Following are the highlights of Tuesday Meeting held on 26-07-2005:

Result:

Total No. of Tested Magnets – 13

Actual No. of Tested Magnets – 12

Magnet underwent thermal cycle - MBBL2189

No. of Tested SSS -4

Tested Special SSS - SSS617

Problem encountered by SM18op Team:

Malfunction of Rotary Switch for Polarity change on Cluster B.

1) Since Rotary switch for Orbital Dipole Corrector Powering is being installed for B cluster, help of equipment support is required for connection of Orbital Dipole Corrector.

2)Cry supervision lost for all the benches.

3) TBE1- Communication error between PLCSE and Server.

4)Faulty Intercon Box of Cluster C was replaced by equipment support.

5)Due to Malfunction of Intercon Box of ClusterF, temporary Cabling arrangement was made by equipment support for selection of electronics for the required bench.

6)Power Test was stopped on MBAL2051 because there was no LQA signal.

7)There was no file transfer to storage folder for SSS036_5. Since OP team can’t validate Data of hfoff from local server, the Data was not validated. Data Validity facility at local server was requested to Marco.

8)TBA1- AC cable soldering was broken. Equipment support will repair.

9)MM mobile rack XMT.MY71 was not working with the magnet on F1. Salem suggested tochange the Rack with the other one.

10)SS152 – HV failed for Sextupole Corrector. Investigation is going on to find out the problem.

11)TBB1 (SSS199)- There was auto trigger during IAP Clamp Corrector. ICS found a bad connection and rectified the connection.

12)TBD1- Communication failure between Server and PLCSE.

13)SPA during MM3 on TBF1. Reason is unknown.

Special points of Meeting

1)Richard suggested to change communication card of PLCSE avoid the frequent problem of Communication between PLCSE and Server.

2)There will be again fatigue test of SSS on D1.

3)There will be fatigue test for Dipole also.

4)There will be Special test for Connection Cryostate on B1.

5)Florence will take care of the test of Q4.

6)White board will be provided for ICS priority.

With regards

Prakash Kashyap