News from today's meeting:

18 magnets tested last week.

1. B Cluster. Helium flow problem in the auxiliary current leads. In case of PLCSE interlocks such as TCLaux_Xx, ask cryo to stabilise the current flow in the auxiliaries.

2. F2. Quench location needed on the current magnet. Shafts will be installed, then possibly LQA if necessary.

3. Next week, either F2 or E2 should be kept free for silver shoe repair.

4. At last, Cluster A should be free from HF loading and MXI problems. A bad contact was discovered, and the VME crate was replaced.

5. Lyre Test. A voltage of 12.06V was observed during a test. This value is within acceptable limits. The important parameter is the stability of the voltage during movement of the magnet. (suggestion from the editor: we should now update the documentation on this subject)

6. Extended Magnetic Measurements will be done on the next magnet on A1.

7. Boris will be asked to provide the facility to validate quench results locally. (in the case where a file is not transmitted)

Happy quenching!

Kevin